full
pattern
#666666
https://visionteknik.com/wp-content/themes/zap/
https://visionteknik.com/
#0095ff
style2

1220 Infinity LC System

Liquid Chromatography

Get A Quote
  • 1220 Infinity LC SystemLiquid Chromatography

  • 1220 Infinity LC SystemLiquid Chromatography

  • Winner of the Scientists’ Choice Award as Best New Separations Product of 2010.
  • Optimized for everyday productivity – exceptional accuracy and superior precision for all routine applications
  • Fully compliant with all requirements for regulatory LC applications.
  • Industry leading quality and long-life – a member of the reliable and trusted 1200 Infinity Series.
  • Fast, trouble-free startup – every system is tested in its final configuration.
  • Flexibility – hardware choices and all-in-one configurations include an isocratic or gradient pump, manual injector or vial autosampler, column oven and variable wavelength detector.
  • Future proof – upgrade your system with additional hardware modules such as a 1200Infinity Series refractive index, fluorescence or evaporative light scattering detector, or a 6000 Series Single Quadrupole MS.
  • Higher resolution and faster run times – our optimized pump delivers up to 600 bars so you can use smaller particle size columns.
  • High pressure capabilities – get up to 600 bars from our integrated autosampler and manual injector.
  • Lower detection limits using a variable wavelength detector up to 80 Hz.
  • Maintain stable temperatures with the optional column oven.
  • High performance software – chose either OpenLAB EZChrom Edition or the fully flexible, multi-purposeOpenLAB ChemStation Edition.
  • Ordering Details
  • Software and Informatics

Agilent 1220 Infinity LC System – Performance Specifications
Safety features Extensive diagnostics, error detection and display, leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas.
Control and data evaluation Agilent EZChrom Compact, Agilent Lab Advisor, Agilent ChemStation, Agilent EZChrom Elite
Communications Controller-area network (CAN), RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN
GLP features Early maintenance feedback (EMF), electronic records of maintenance and errors
Agilent 1220 Infinity LC System – Performance Specifications Pumps (isocratic and gradient)
Hydraulic system Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and passive inlet valve
Settable flow range 0.001 – 10 mL/min, in 0.001 mL/ min increments
Flow range 0.2 – 10.0 mL/min
Flow precision <0.07% RSD, or < 0.02 min SD whatever is greater, based on retention time at constant room temperature
Flow accuracy ± 1% or 10 μl/min whatever is greater
Pressure Operating range 0 – 60 MPa (0 – 600 bar, 0 – 8700 psi) up to 5 mL/min
Operating range 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi) up to 5 mL/min
Operating range 0 – 20 MPa (0 – 200 bar, 0 – 2950 psi) up to 10 mL/min (all versions)
Pressure pulsation < 2 % amplitude (typically < 1 %), at 1 mL/min isopropanol, at all pressures > 1 MPa (10 bar)
Compressibility compensation User-selectable, based on mobile phase compressibility
Recommended pH range 1.0 – 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
Gradient formation (gradient pump or optional; two solvents) Low pressure dual mixing/gradient capability using proprietary high-speed proportioning valve
Pump delay volume 600 – 900 μl, system delay volume 800 – 1100 μl, dependent on back pressure
Composition range 0 – 95 % or 5 – 100 %, user selectable
Composition precision < 0.2 % RSD or < 0.04 min SD, whatever is greater, at 1 mL/min; based on retention time at constant room temperature
Agilent 1220 Infinity LC System Performance Specifications – Integrated degassing unit (gradient pump only)
Maximum flow rate 10 mL/ min per channel
Number of channels 2
Internal volume 1.5 mL/ channel
Agilent 1220 Infinity LC System – Performance Specifications Autosampler
Pressure Operating range 0 – 60 MPa (0 – 600 bar, 0 – 8700 psi)
Injection range 0.1 – 100 μL in 0.1 μL increments
Up to 1500 μL with multiple draw (hardware modification required)
Replicate injections 1 – 99 from one vial
Precision < 0.25% RSD from 5 – 100 μL, < 1% RSD 1 – 5 μL variable volume
Minimum sample volume 1 μL from 5 μL sample in 100 μL microvial, or 1 μL from 10 μL sample in 300 μL microvial
Carryover Typically < 0.1%, < 0.05% with external needle cleaning
Sample viscosity range 0.2 – 50 cp
Sample capacity 100 × 2-mL vials in 1 tray
40 × 2-mL vials in ½ tray
15 × 6-mL vials in ½ tray (Agilent vials only)
Injection cycle time Typically 50 s depending on draw speed and injection volume
Agilent 1220 Infinity LC System – Performance Specifications Oven
Temperature range 5 °C above ambient to 80 °C
Temperature stability ± 0.15 °C
Temperature accuracy ± 0.8 °C with calibration ± 0.5 °C
Column capacity One 25-cm column
Internal volume 6 μL

 

Agilent 1220 Infinity LC System Performance Specifications Variable Wavelength Detector
Detection type Double-beam photometer
Light source Deuterium lamp
Wavelength range 190 – 600 nm
Short term noise ± 0.35 × 10-5 AU, at 230 nm
Drift 3 × 10-4 AU/hr, at 254 nm
Linearity > 2 AU (5%) upper limit
Wavelength accuracy ± 1 nm; Self-calibration with deuterium lines, verification with holmium oxide filter
Band width 6.5 nm typical
Flow cells Standard: 14- μL volume, 10-mm cell path length and 40 bar (588 psi) pressure maximum
High pressure: 14- μL volume, 10-mm cell path length and 400 bar (5880 psi) pressure maximum
Semi-micro: 5- μL volume, 6-mm cell path length and 40 bar (588 psi) pressure maximum
Agilent 1220 Infinity LC System Performance Specifications Diode Array Detector (G4294B only)
Detector type 1024-element diode array
Light source Deuterium and tungsten
Number of signals 8
Maximum sampling rate 80 Hz
Short-term noise < ± 0.7 x 10-5 AU at 254/4 nm and at 750 nm, TC 2 s
Drift < 0.9 x 10-3 AU/hr at 254 nm
Linearity > 2.0 AU (5 %) at 265 nm
Wavelength range 190-950 nm
Wavelength accuracy ± 1 nm, self-calibration with deuterium lines verification with holmium oxide filter
Slit width Programmable: 1, 2, 4, 8, 16 nm
Diode width < 1 nm

Agilent 1220 Infinity Mobile LC SolutionAgilent 1220 Infinity Mobile LC Solution with integrated variable wavelength or diode array detector.

Found In : Data Sheet | Date: Jul 04, 2012 | FileSize: 0.706 MB

Agilent 1220 Infinity Mobile LC SolutionAgilent 1220 Infinity Mobile LC Solution with integrated variable wavelength or diode array detector.

Found In : Data Sheet | Date: Jul 04, 2012 | FileSize: 0.706 MB

seta