The UM-II and CONTROLLER collect data from up to 32 locations via multiplexed monitoring. Lighthouse’s manifold design allows shorter purge times, increasing the number of samples per day. Users configure and control the system and can view sampling data on the Manifold Controller. The Controller can be placed up to 4,000 feet from the Manifold to allow control and viewing of data from a more convenient location. The UM-II and CONTROLLER perform user programmable data sampling and will alarm should a low-flow condition occur.
The UM-II and CONTROLLER interface with Lighthouse particle counters and existing building automation and facility management systems, providing the lowest cost per point on the market.
Multiplexed Monitoring of Up to 32 Locations
Color LCD Display
Localized Control
User Programmable Sampling
Localized Data Viewing (Current and Historical)
Low Flow Alarm
Reduced Purge Times
RS-485 MODBUS
Stainless Steel Construction
Building Automation
Facility Management Systems Interface
2 Year Warranty
Cost Effective Price per Point
Easy System Integration
International Support
Low Cost of Ownership
Cleanroom Monitoring
Facility Monitoring
SMIF and FIMS Enclosure Monitoring
Cleanroom Performance Verification
Large Area Monitoring
Trend Analysis
Cleanroom Laundries
Cleanroom Packaging
Semiconductor
Aerospace
Hard Disk Drive Manufacturing
Pharmaceutical Packaging and Manufacturing
Specifications
Specifications
Manifold:
Sample Ports:
32
Flow Rate:
3 CFM (84.9 LPM) per port (nominal)
Cross-Port Contamination:
Particle Sample Tubing:
Particle transport tubing 1/2” OD, 3/8” ID (1.25 cm OD, 0.94 cm ID)
Sample Tubing Length:
Up to 115 feet (35 m) per port
Fittings Provided:
32 Barbed Port Fittings, 1/2” (1.25 cm) OD tubing connection
Power:
24 VDC
Dimensions:
21.6” (l) x 12” (w) x 12.75” (h)
Weight:
16 lbs 6 oz
Manifold Controller:
Compatible Software:
Lighthouse Monitoring System; LMS Express, Express RT and RT+ software; communicates with most other manufacturers’ Building Automation Systems and Factory Automation Systems
Communications Protocol:
RS-485/MODBUS
Dimensions:
5.75” (l) x 8” (w) x 6.75” (h)
Weight:
4 lbs 6 oz
Optional Manifold Blower:
Safety Provision:
Automatic pump shut-off
Power:
208, 415 VAC – Three Phase
Dimensions:
15” (w) x 20” (h) x 16.7” (l) [47 x 38 x 51 cm]
Weight:
75 lb (34 kg)
Conditions
Conditions
Operating:
50°F to 104°F (10°C to 40°C) / 20% to 95% non-condensing
Storage: